Data

CCAT 6A INST-FRNC

CAT 6A installation cable

The permanent installation of indoor cables means that flexibility is not the main issue here but that in case of fire cables must be as nonpolluting  as possible, i.e. they should comply with CPR safety requirements. To cope with a growing data amount, our CCAT 6a INST-FRNC transmits within a bandwidth of 600 MHz according to Ethernet data category 6a standards. As this cable is equipped with pair shield foils (PiMF, U/FTP) and strong copper conductors (AWG 23) it allows remarkably low-loss data transmission over long distances and also supports the power supply over EtherNet (PoE). The CCAT 6A INST-FRNC network cable is flame-retardant and halogen-free and complies with the European  CPR fire classification Dca. 

Highlights (Main Properties)

FRNC jacket, flame-retardant and halogen-free for permanent indoor installations

complies with the standards IEC 60332,  IEC 60754 and IEC 61034 and the European CPR fire classification Dca

data category Cat 6A

U/FTP (PiMF) individual pair shielding of the 4 conductor pairs 

AWG 23/1, strong solid conductors with low attenuation for long transmission distances

PoE (Power over EtherNet) according to IEEE 802.3at (25.5W)

Available lengths: 100m, 500m

Product information
Conductor area 0.26 mm²
AWG AWG 23
Composition of conductor 8 x 7 x 1.32
Material bare copper
Conductor resistance 75 Ohm/km
Shielding U/FTP
Capacity cond.-cond. (pF/m) 45 pF/m
Specifications / Tender
Technical facts
Type CAT 6A data installation cable
Part no. CCAT 6A INST-FRNC

Mechanical data

Conductor area 0,16 mm² (AWG 23/1)
Composition of conductor 1 x 1,32 mm massive bare copper
Conductor isolation PE
Composition of cores 4 pairs twisted
Screen S/UTP
Pair Screen foil (AL/PT)
Overall jacket FRNC compound, Orange, RAL 2003
Overall diameter 7,3 mm
Weight 50 g/m
Working temperature  
mobile (0 °C) - (+50 °C)
fixed (-20 °C) - (+60 °C)
min.Bending radius  
mobile 8x overall diameter
fixed 4x overall diameter
Electrical data  
Conductor resistance 75 Ω / km
Capacity (cond./cond.) 45 nF / km
Attenuation  
1 MHz 1,9 dB (100m)
4 MHz 3,5 dB (100m)
10 MHz 5,6 dB (100m)
20 MHz 7,9 dB (100m)
100 MHz 17,8 dB (100m)
200 MHz 25,1 dB (100m)
500 MHz 41,8 dB (100m)
Characteristic impedance 100 Ω ± 5 % (100 MHz)
Crosstalk Attenuation (NEXT)  
1 MHz 100 dB (100m)
4 MHz 100 dB (100m)
10 MHz 100 dB (100m)
20 MHz 100 dB (100m)
100 MHz 98 dB (100m)
200 MHz 93 dB (100m)
500 MHz 83 dB (100m)
Test voltage 700 V eff.
Downloads
Product variants
Colour Part number
CCAT 6A INST-ORANGE 100 FRNC
CCAT 6A INST-ORANGE 500 FRNC
Sales consultant
Franky Kolken
Sales consultant
Regina Tegel
Sales consultant DACH
Thomas Murawski
Technical support
Günter Schäfer